Home > orifice plate complete with its tapping flange for boiler steam

orifice plate complete with its tapping flange for boiler steam

About Us

Zozen Boiler main products include gas&oil boiler, coal-fired boiler, biomass boiler, thermal fluid heater and other series of more than 400 varieties of specifications.
Contact us for Email:[email protected]

Our Main Product

our main boilers
wns boiler picture

1-20 ton gas/oil fired boiler

Price: $12000-$450000/set

Capacity: 1-20 ton/h

Pressure: 0.7-2 Mpa

Fuel: Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.

Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

szs boiler picture

7-70 MW gas/oil fired hot water boiler

Price: $160000-$1800000/set

Capacity: 7-70 MW

Pressure: 1.0-1.6 Mpa

Fuel: Nature gas, coke oven gas, blast furnace gas, carbon black off-gas, biogas, methanol, LPG, diesel, heavy oil, light oil, crude oil, etc.

Industries: Heat supplying, hospital, colleges and universities.

szl boiler picture

2.8-29mw coal fired boiler

Price: $70000-$750000/set

Capacity: 2.8-29mw

Pressure: 1.0-1.25 Mpa

Fuel: Bituminous coal, lean coal, anthracite

Industries: Heating, hotels, schools, hospitals

yyw boiler picture

horizontal thermal fluid heater

Price: $12000-$350000/set

Capacity: 700 - 14000 kw

Pressure: 0.8 - 1.0 Mpa

Fuel: natural gas, coke oven gas, bio-gas´╝îliquid propane gas, diesel, heavy oil, light oil, crude oil

Industries: Petroleum, chemical, chemical fiber, pharmaceutical, textile printing and dyeing, building materials, wood processing, vegetable oil processing and other industries

dzl boiler picture

1-20 ton biomass fired boiler

Price: $12000-$350000/set

Capacity: 1-20 ton/h

Pressure: 0.7-2.5 Mpa

Fuel: Biomass particles

Industries: Heating, chemical, food, tobacco, textile, printing and dyeing, feed, medicine, building material, wine, rubber, hospital

Orifice plate flowmeters for steam, liquids and

Check on steam boiler efficiency Carrier plate for clamping between flanges. Downstream pressure tapping that the full potential of the orifice plate primary element is not achieved. . 1) On its own fitted between flanges with pressure.

Flow Meter Guide

ure 1, they are the measurement orifice plate, which is in- stalled in the . gas or steam through an orifice to the flow that is predi- cated by the As its name implies, this plate has the . clude corner taps, flange taps, full flow (or pipe) taps, ra- dius tapes . flows, such as the detection of combustion air to boilers or air flow to

Best Practice Guide Impulse Lines for - IDC

such as an orifice plate, a nozzle, or a Venturi meter, impulse lines are used to connect covers impulse lines but not the pressure tappings (their diameter, edge . such as measurement of steam flow where the steam saturation temperature Table 3: Recommended pressure tapping locations from ISO/CD 2186:2004 for.

Energy Management Measurement Best Practices and

piping requirements. Eliminate impulse lines. Measure mass flow in gas steam . Minimizes Compressor, Pump or Boiler Size . Flange-tap Orifice Plate.

Differential Pressure Flowmeters - OMEGA

The orifice plate is commonly used in clean liquid, gas, and steam service. Flange taps, corner, and radius taps can all be used with quadrant-edged orifices , . However, they may also require more straight pipe run to condition their flow .. pitot stations are used to measure the large flows of low pressure air in boilers ,

Products | Flowell

Flowell manufactures Meter Tubes utilizing orifice flanges, orifice fittings and other Type Orifice Plates are designed to be used with ring joint plate holders. Flowell Studding Outlets are manufactured in accordance with ASME Boiler and to bleed gas or liquid from a line, they may also be manufactured with a full []

Steam and Condensate - Orifice Plate Steam Traps

Orifice Plate Steam Traps. The big difference with all other types of steam traps is that orifice plate steam traps have no moving parts. The operation of the orifice

Flange Types - Wermac.org

This flange type will be welded to a pipe or fitting with a single full penetration, Neck flanges, and their life under fatigue is about one-third that of the latter.

Startup Service Maintenance - Weil-McLain

sufficient to keep the boiler at steaming temperature Water Sytems: The boiler and the entire system should operating instruction plate which is mounted on the boiler skim tapping and run this line to a convenient . nections to the boiler and its auxiliaries. .. Type Heating Valve Standard Orifice Gas BTU/cu. ft. Size _

Basic Instrumentation Measuring Devices And Basic

explain the reason for the use of reset (integral) control and its units;. sketch the pressure when completely vented down to atmosphere - it would not indicate .. Orifice Plate with Flange Taps and Three Valve Manifold. Corner Taps installation. One use of elbow taps is the measurement of steam flow from the boilers,.

Orifice Flange Tap Routing and Orientation -

Nov 4, 2013 regarding the routing of the piping to flange taps around an orifice plate. Our orifice plates are in a feedwater line and are measuring the flow feeding a boiler. arithmetic to convert dP to flow--it is Bernoullis equation at its root. line is full then it just doesnt matter what orientation you put the taps in,

Development of Orifice Meter Standards Technical

at the orifice meter standards, what is their value and what we can expect in The meter had flange taps. used pipe taps (2.5D, 8D) and Bailey Meter Company made . U.S. Naval Boiler and Turbine Laboratory tests (1948-1954). expansion factors for steam. . Unauthorized duplication in whole or in part is prohibited.

Reducing energy consumption costs by steam

5.3 Orifice plate meter . centralised boiler plant supplying steam to all users on a site. measuring the steam flow to an entire factory allows . reducing its pressure necessarily decreases its . necessary to fit a new, flanged spool piece or . Downstream pressure tapping. Upstream pressure tapping. P Ouput to DP cell.

BOILER MOUNTINGS AND CONTROL EQUIPMENT FOR -

Boiler Mountings is the overall description applied valves, main steam stop valves, inspectors test con- general uprating of Mild Steel and Copper flanges, valve manufacturers have had to investigate their thus completing the converging-diverging nozzle. The .. An orifice plate can be placed in series with a valve.

Orifice Flanges on ThomasNet.com

Results 1 - 25 of 89 Custom manufacturer of orifice plate flanges. Pipe, back-up, blind, boiler, manhole, tank, lap joint, threaded, pump, expansion Orifice flanges have radial , tapped holes in flange ring for meter connections bolts. Full line of stainless alloy plate flame cutting, also galvanized carbon steel flanges.

Instrument lesson - SlideShare

Jun 30, 2014 Variables such as boiler level, temperature and pressure, turbine speed Before any process can be controlled, its current status must be known. of high pressure steam, high voltage, toxic gases, corrosive liquids, etc., Removing Flow Transmitter From Service Figure 4: Orifice Plate with Flange Taps

Piping engineering guide - SlideShare

Jan 30, 2015 Orifice Flange Rolta Training Center, Mumbai India 94 Safety valve outlet . To complete the project within the planned completion period. Some companies even publish their own internal piping standards based upon .. As steam begin to reach orifice plate the condensate will begin to expand.

Tech Talk (6) Flow Measurement Basics (Part 1) -

orifice plate or flow tube coupled to a manometer regardless of its temperature and pressure . accuracies of 2%4% of full-scale such as wet steam, the sharp edge and . Flange taps placed 1 in (25.4 mm) . Boiler and turbine leads.

OM Model-MiniPack-SW-PilotOperated 1114. - Ace

Stud Nuts: During shipment, the bonnet and shell flange nuts may loosen and Orifice Plate: All Mini-Packs come with an orifice plate inside a union on the The Mini-Pack uses boiler steam or hot water as its heating medium. It is assumed that installation is complete and that all connections have been made, including:.

PN25 - Crane Fluid Systems

of the English Company and changed its name to full range of traditional valves: ball, single/multi boiler or calorifier . water, gas and steam . DRAINING TAP (Note 1) Valves are suitable for use with flanges conforming to BS EN 1092-2 PN10 or . DM900 is a stainless steel orifice plate which has a square edged.

GET Support & Price

Please Feel free to give your inquiry in the form below.We will reply you in 24 hours