Home > 80 ton Low Pressure Waste Heat Boiler in the power plant

80 ton Low Pressure Waste Heat Boiler in the power plant

About Us

Zozen Boiler main products include gas&oil boiler, coal-fired boiler, biomass boiler, thermal fluid heater and other series of more than 400 varieties of specifications.
Contact us for Email:[email protected]

Our Main Product

our main boilers
wns boiler picture

1-20 ton gas/oil fired boiler

Price: $12000-$450000/set

Capacity: 1-20 ton/h

Pressure: 0.7-2 Mpa

Fuel: Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.

Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

szs boiler picture

7-70 MW gas/oil fired hot water boiler

Price: $160000-$1800000/set

Capacity: 7-70 MW

Pressure: 1.0-1.6 Mpa

Fuel: Nature gas, coke oven gas, blast furnace gas, carbon black off-gas, biogas, methanol, LPG, diesel, heavy oil, light oil, crude oil, etc.

Industries: Heat supplying, hospital, colleges and universities.

szl boiler picture

2.8-29mw coal fired boiler

Price: $70000-$750000/set

Capacity: 2.8-29mw

Pressure: 1.0-1.25 Mpa

Fuel: Bituminous coal, lean coal, anthracite

Industries: Heating, hotels, schools, hospitals

yyw boiler picture

horizontal thermal fluid heater

Price: $12000-$350000/set

Capacity: 700 - 14000 kw

Pressure: 0.8 - 1.0 Mpa

Fuel: natural gas, coke oven gas, bio-gas,liquid propane gas, diesel, heavy oil, light oil, crude oil

Industries: Petroleum, chemical, chemical fiber, pharmaceutical, textile printing and dyeing, building materials, wood processing, vegetable oil processing and other industries

dzl boiler picture

1-20 ton biomass fired boiler

Price: $12000-$350000/set

Capacity: 1-20 ton/h

Pressure: 0.7-2.5 Mpa

Fuel: Biomass particles

Industries: Heating, chemical, food, tobacco, textile, printing and dyeing, feed, medicine, building material, wine, rubber, hospital

Low-temperature Waste Heat Utilize

FOC has been working on a technology that utilizes low-grade waste heat with plant at temperatures between 80ºC to 150ºC is used to heat water piped in from Chemical plants boiler to a temperature of 110ºC via a heat exchanger. high -pressure ammonia which then powers the electric power generation turbine.

Wood to Energy: Heat and Power Applications1 -

the waste heat from the electricity production process to use as heat or steam. Most power plants use fuel to generate steam with boilers and then of fuel at 80 percent efficiency. low-pressure steam, but the process reduces the amount of electricity 10,000 tons per year of wood waste, and creates improved working.

Waste Heat Recovery System - Marine Engines

Waste Heat Recovery System (WHRS) for Reduction of Fuel Consumption, . 80 MWmech. WHR System - Configuration: Dual pressure exhaust gas boiler Sum Power Generation (ST/PT): 2 9 MWel closed at an engine power lower than 319 tons. SOx emission saving per year: 214 tons. Particulates saving per

Central Energy Facility (CEF) - Cardinal Cogen |

Stanfords Central Energy Facility is a combined heat and power plant comprised of four facilities: Boiler Plant; Chilled Water Plant; Cogeneration Plant; Ice Plant The waste heat in the form of low-pressure steam is distributed to campus and of ice storage and chillers, the Ice Plant can produce 20,000 tons of cooling

Enhanced power and heat generation from bio mass

biomass- burning plants, the power and heat generation can be substantially superheater for the low temperature steam from the waste boiler, an effective is then improved to suit a rather large back pressure steam turbine with heat The exhaust gas flow of 80 kg/s has a temperature of 535°C at nominal conditions.

Solutions | Marquette Green Energy, LLC (MGE)

CHP is a type of distributed generation, which, unlike central station generation, using high-pressure steam from a fired boiler before sending lower pressure steam to Waste heat streams can be used to generate power in what is called of 45 percent, CHP systems can operate at efficiency levels as high as 80 percent.

Combined Heat Power (CHP) Success Stories -

Their combined heat and power plants help meet the electrical and thermal The engines burn natural gas and use 3-way catalysts to lower NOx emissions. . This system is supplemented by three 500,000-lbs/hr boilers with back pressure a 6,300-ton chiller and producing 115,000 lb/hr of steam using a waste heat

Waste Heat Recovery - Optimising your energy

lava measured 80 exajoules; enough energy to keep all the worlds .. from steam boilers. Recovering waste heat often reduces the need for steam in a plant .

Waste Heat Recovery Power Generation Systems for

Aug 18, 2015 Cement production process is highly energy intensive with approximately 3-4-GJ energy consumption per ton of cement produced. Moreover

BOILERS THERMIC FLUID HEATERS - RETScreen

The hot water or steam under pressure is then Waste heat boiler and Thermic fluid heater. . The lower combustion temperature is achieved because of high coefficient of heat (steam and electricity) or combined cycle power generation. .. blowdown, can recover up to 80% of the energy contained in the blowdown.

Back Pressure Turbine

Back Pressure Turbine, CHP systems, Turboexpander and Waste Heat Recovery facilities where there are large amounts of low pressure process steam available. The resulting power generation efficiency (modern steam boilers operate at tons each, and the third Hitachi Absorption Chiller was rated at 1,500 tons.

Introduction - CHAMCO.net

Municipal Solid Waste (MSW) is the primary hazard to the environment and people of of the engine can be used for a low pressure Waste Heat Recovery Boiler. MSW gasification power plant needs about 80 Tons of MSW Briquettes / day.

3. Current application of bagasse for co-

Legal framework for biomass power generation in Vietnam. 5. Cane yield 80 tons per ha motor, apply continuous technology , apply waste heat recovery system , BACKWARD technology including low pressure boiler 45 ata, and.

Waste heat recovery of dura (Iraq) oil refinery

An alternative cogeneration energy plant is presented in the second part of this chamber Electrical Heat exchanger High pressure Low pressure Thermal An additional 11 MWe of electrical power is purchased from the main electric network. 9.4 Waste heat recovery 267 cogeneration) plants use a separate boiler to

Novel Application of Organic Rankine Cycle (ORC

Tel: +90 328 826 80 80 The natural gas burning furnace has a 250 tons/hour maximum operate at lower temperatures and take advantage of waste heat generated at Physical Layout of Rankine Cycle Power Generation Equipment Cooling water at a pressure of around 0.27 MPa (39 psi) is maintained in a drum

Kendall Cogeneration Station - Veolia North

and government facilities for more than 80 years. Acquired by energy system integrates Combined Heat and Power housed power boilers and steam turbines to has leveraged a portion of the plants waste heat, a 475,000 tons additional power and low pressure Green Steam which is delivered to customers.

Waste Heat Recovery - U.S. Department of Energy

Feb 13, 2015 a plant. The largest sources of waste heat for most industries are exhaust and .. Heat losses from boilers are in the low temperature range,

UEM s Power Plant Efficiency Study - The

Likewise, operating a combined heat and power plant allows for higher waste heat. In 1996, the natural gas boilers for heating, the benefits are even in fuel costs and prevented the release of millions of tons of CO2. In a common setup, superheated steam is taken from the low pressure section of a steam turbine.

Woody Biomass Power Generation Technology

Power generation efficiency can be as high as 20% and the waste heat can also be utilized. Woody biomass is unique in that its gasification temperature is low while maintaining the temperature and pressure in order to avoid tar recovery boiler 80 kW, which is equivalent to the power requirements for about 30.

How to decide if an absorption chiller right for

Sep 11, 2012 Because absorption chillers use waste heat as the driver for the Low-pressure steam will be supplied by a 78% efficient boiler plant. . The calculation which you made for 100 ton power consumption, .. what if X amount heat source is reduced to 80% or 70% only, while the chiller is already running?

GET Support & Price